Starting Time: | 0.5 sec. or less, to reach double of specified wow & flutter value |
Tape Timer: | 0.5% timing and repeated timing accuracy. Indicating minutes and seconds, real time indication for 19 cm /s |
Rewind Time: | Approx. 120 sec. for 700m (2300 ft.) reel |
Stopping Time: | 5 sec. or less from fast winding mode |
Operational Tape Tension: | 90p ±10p during play and fast winding mode |
Tape Tension Max.: | 600p at start, stop and change of wind direction |
Frequency Response (Record-Response): | 30Hz to 18kHz, ±2dB (38 cm / s)
60Hz to 15kHz, ±1dB (38 cm / s)
30Hz to 15kHz, ±2dB (19 cm /s)
60Hz to 12kHz, ±1dB (19 cm /s)
40Hz to 12kHz, ±2dB (9.5 cm / s)
60Hz to 10kHz, ±1dB (9.5 cm / s) |
[S / N Ratio] | |
Full track (6.3mm track width): | 65dB (38 cm / s)
65dB (19 cm /s)
63dB (9.5 cm / s) |
Stereo (2.75mm track width): | 62dB (38 cm / s)
62dB (19 cm /s)
60dB (9.5 cm / s) |
Two track (2mm track width): | 61dB (38 cm / s)
61dB (19 cm /s)
59dB (9.5 cm / s) |
Equalization: | Switchable NAB or CCIR |
Crosstalk rejection: | 40dB or more, 80Hz to 12kHz (1kHz: -45dB) |
Erasure Efficiency: | 75dB or more at 1kHz (38 cm / s) |
Erasure and Bias Frequency: | 150kHz at all tape speeds |
Line Inputs: | Balanced and floating
Input impedance - 5kΩ |
Input Levels: | -20 dBm min.
+22 dBm max. |
Line Outputs: | Balanced and floating
Output impedance - 50Ω or less
200Ω min. load impedance |
Output Levels: | +22 dBm / 600Ω
+20 dBm / 200Ω |
VU-Meter: | ASA-Standard, meter switchable +4 dBm, +6 dBm, +8 dBm
Peak indication (LED) by IEC recommendation |